SantoLubes LLC
Findett, Santotrac, Santovac, Santolubes, and Synergy

Material Safety Data Sheet

  1.  CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NAME:  MCS-2408 Lubricant Fluid

ARCH TECHNOLOGY HOLDING LLC, 8 Governor Drive, St. Charles, MO 63301

636-723-0240

Chemical Family:  Aliphatic polyester
Chemical Name:  MCS-2408

FOR CHEMICAL EMERGENCY, SPILL LEAK, FIRE, EXPOSURE, OR ACCIDENT:   Call CHEMTREC - Day or Night - 800-424-9300.  Toll free in the continental U.S., Hawaii, Puerto Rico, Canada, Alaska, or Virgin Islands.  For calls origination else where:  703-527-3887 (collect calls accepted).

  2.  COMPOSITION/INFORMATION ON INGREDIENTS

MCS-2408 lubricant is a proprietary fluid mixture.  All components of MCS-2408 lubricant appear on the inventory of Chemical Substances published by the U.S. Environmental Protection Agency under the authority of the Toxic Substances Control Act. (TSCA).

  3.  HAZARDS IDENTIFICATION

sara Hazard Notification

Hazard Categories Under Criteria of SARA Title III Rules (40 CFR Part 30):  None

Section 313 Toxic Chemical(s):  Not Listed

  4.  FIRST AID MEASURES

HANDLE IN ACCORDANCE WITH GOOD INDUSTRIAL HYGIENE AND SAFETY PRACTICES.  THESE PRACTICES INCLUDE AVOIDING UNNECESSARY EXPOSURE AND REMOVAL OF MATERIAL FROM EYES, SKIN AND CLOTHING.

  5.  FIRE FIGHTING MEASURES

Flash Point:  470°F                  Method:  Cleveland Open Cup

Extinguishing Media:  In case of fire, use water spray, foam, dry chemical, carbon dioxide or any Class B extinguishing agent.

Special Fire Fighting Procedures:  Fire fighters and others exposed to products of combustion including carbon monoxide, lower molecular weight hydocarbons and smoke can occur.  Oxides of phosphorous may also be present.

 

  6.  ACCIDENTAL RELEASE MEASURES

Emergency Spill and Leak Information:  Contain fluid.  Transfer liquid to containers for recovery or disposal.  Absorb small leaks on clay or sawdust for disposal.

  7.  HANDLING AND STORAGE

HANDLE IN ACCORDANCE WITH GOOD INDUSTRIAL HYGIENE AND SAFETY PRACTICES.  THESE PRACTICES INCLUDE AVOIDING UNNECESSARY EXPOSURE AND REMOVAL OF MATERIAL FROM EYES, SKIN AND CLOTHING.

Emptied container retains vapor and product residue.  Observe all labeled safeguards until container is cleaned, reconditioned, or destroyed.

Storage:  Product is stable under normal conditions of storage and handling.

  8.  EXPOSURE CONTROLS/PERSONAL PROTECTION

Eye Protection:  MCS-2408 does not cause significant eye irritation or eye toxicity requiring special protection.  Use good industrial practice to avoid eye contact.

Skin Protection:  Although MCS-2408 does not present a significant skin concern, minimize skin contamination by following good industrial practice.  Wearing protective gloves is recommended.  Wash hands and contaminated skin thoroughly after handling.

Respiratory Protection:  MCS-2408 is not likely to present an airborne exposure concern under normal use.  Use NIOSH/MSHA approved respiratory protection equipment if needed for mist and vapor exposure during unusual handling conditions. Consult respirator manufacturer to determine appropriate type equipment for given application.  Observe respirator use limitations specified by NIOSH/MSHA or the manufacturer.  Respiratory protection programs must comply with 29 CFR §  1910.134.

Airborne Exposure Limits:  

MCS-2408  

  9.  PHYSICAL AND CHEMICAL PROPERTIES

Appearance:                      Clear, moderately light yellow liquid

Odor:                                 Mild inoffensive odor

Vapor Pressure @ 20°C:    < 1mm Hg

Vapor Density (air = 1):      > 1

Viscosity   @210°F:            8.5–9.5 cs
                 @100°F:           53.3 cs

Solubility:                          Negligible

NOTE:  These physical data are typical values based on material tested but may vary from sample to sample.  Typical values should not be construed as a guaranteed analysis of any specific lot or as specifications for the product.

  10.  STABILITY AND REACTIVITY

Stability:  MCS-2408 is stable under normal conditions of storage and handling.

Materials to Avoid:  Strong acids or alkalis; strong oxidizing agents.

Hazardous Decomposition Products:  This product will generate carbon monoxide (CO), carbon dioxide (CO2), lower molecular weight hydrocarbons, smoke and soot when burned.  Oxides of phosphorus may also be present.

Hazardous Polymerization:  Does not occur.

  11.  TOXICOLOGICAL INFORMATION

The following information presents both human experience and the results of scientific experiments used by qualified experts to assess the effects of MCS-2408 on the health of exposed individuals and to support precautionary statements and Occupational Control Procedures recommended in this document.  Proper evaluation of this health-related data may require the assistance of individuals trained in interpretation of this type of information.

Effects of Exposure

Dermal contact and inhalation are expected to be the primary routes of occupational exposure to MCS-2408.  Occupational exposure to this material has not been reported to cause significant adverse health effects.  On the basis of available information, exposure to MCS-2408 is not expected to produce significant adverse human health effects when recommended safety precautions are followed.

Toxicological Data

Data from studies with MCS-2408 indicate the following:

Oral LD50 (Rat): > 5,000 mg/kg, Practically Nontoxic
Dermal LD50 (Rabbit):  >5,000 mg/kg, Practically Nontoxic
Eye Irritation (Rabbit, 24-hr):Slightly Irritating All animals were free of ocular irritation within 24 to 48 hours
Skin Irritation (Rabbit, 4-hr):Slightly Irritating 1.4 on a scale of 8.0
All animals were free of dermal irritation within 7 to 10 days.

Components

Data from the available literature on a aliphatic ester component of MCS-2408 are discussed below:

Aliphatic Ester

The results of acute toxicity tests indicate that this material is practically nontoxic to rats and mice (LD50 between 12,800 and 25,600mg/kg) by ingestion in single doses.  No mortality and no signs of toxicity were observed in male rats exposed to 250 mg aliphatic ester/m3 of air for 4 hours.  Administration of the aliphatic ester to four male rats at a dietary level of 3% for 3 weeks was reported to induce hepatic peroxisome proliferation increases in liver weight and activities of peroxisome — associated enzymes, and a decrease in serum lipids.  No mutagenic effects were reported in microbial assays using four Salmonella strains, with and without mammalian microsomal activation.


  12.  ECOLOGICAL INFORMATION

SantoLubes LLC has not conducted environmental toxicity studies with this product.

  13.  DISPOSAL CONSIDERATIONS

This material when discarded is not a hazardous waste as defined by the Resource, Conservation and Recovery Act (RCRA), 40 CFR 261.  Dispose of in accordance with all federal, state and local environmental regulations.  Recommended method of disposal is by high temperature incineration at a RCRA approved TSDF.  If there are any questions regarding the disposal of this material, please consult the Environmental, Health & Safety Department of SantoLubes LLC at 636-946-2355.

  14.  TRANSPORT INFORMATION

DOT Proper Shipping Name:Not Applicable
DOT Hazard Class/I.D. No.:This product is not classified as a hazardous material by the U.S. Department of Transporation.
DOT label(s):Not Applicable
U.S. Surface Freight Class:Lubricating oil NOIBN

Reportable Quantity (RQ) Under U.S. EPA CERCLA Regulations:  None Listed

  15.  REGULATORY INFORMATION

SARA Hazard Notification

Hazard Categories Under Criteria of SARA Title III Rules (40 CFR 30):  None

Section 313 Toxic Chemical(s):  Not Listed

  16.  OTHER INFORMATION

Reason for revision:  Header

Revision number:  3

NOTICE:  Although the information and recommendations set forth herein (hereinafter "Information") are presented in good faith and believed to be correct as of the date hereof, SantoLubes LLC makes no representations as to the completeness or accuracy thereof.  Information is supplied upon the conditions that the persons receiving same will make their own determinations as to its suitability for their purposes prior to use.  In no event will SantoLubes LLC be responsible for damages of any nature whatsoever resulting from the use of or reliance upon information.  NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESSED OR IMPLIED, OR MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OF ANY OTHER NATURE ARE MADE HEREUNDER WITH RESPECT TO INFORMATION OR THE PRODUCT TO WHICH INFORMATION REFERS.

Date:  10/14/05                                                                   Supersedes:  10/29/2001